Surpria: Software Version V3.11, V3.22 — FDA record Z-1749-2022
Reported ongoing
Status as reported in the agency record. FDA warns that enforcement status may not track the current recall lifecycle; check the current official notice.
Source date Jul 12, 2022. Retrieved Oct 1, 2026. Last updated Oct 1, 2026.
Archive changed Oct 1, 2026. USDA FSIS records are unavailable; check FSIS directly. Source coverage and dates.
What the record says
- Product
- Surpria: Software Version V3.11, V3.22
- Reason
- Error 00003050 or 00003052 may occur during scanning, the captured images will not be reconstructed and the Raw Data will not be displayed in the work list.result, may result in the need for additional scanning to capture the images properly for reconstruction, thereby exposing the patient to additional radiation
- Classification
- Class II
- Recalling firm
- FUJIFILM Healthcare Americas Corporation
- Quantity
- 20 units
- Agency-reported status
- Ongoing
- Source record identifier
- Z-1749-2022
What the recall classes mean. Classification is an agency assessment, not individual medical advice.
Lot and product identifiers
| Label field | Details supplied by the agency |
|---|---|
| Lot, code or applicability | UDI: (01)04580292766601(11)200130(21)W5067(250)G560045319 (01)04580292766601(11)200220(21)W5068(250)G560048119 (01)04580292766601(11)200902(21)W5069(250)G560071519 (01)04580292766601(11)201210(21)W5070(250)G560075519 (01)04580292766601(11)201225(21)W5071(250)G1Z0040620 (01)04580292766601(11)210218(21)W5072(250)G1Z0063520 (01)04580292766601(11)210512(21)W5073(250)G1Z0244920 (01)04580292766601(11)210519(21)W5074(250)G1Z0048121 (01)04573596200520(11)210818(21)W5075(250)G1Z0083221 (01)04573596200520(11)210903(21)W5076(250)G1Z0094621 (01)04573596200520(11)210903(21)W5077(250)G1Z0094521 (01)04573596200520(11)210903(21)W5077(250)G1Z0094521 (01)04573596200520(11)211018(21)W5079(250)G1Z0123621 (01)04573596200520(11)211115(21)W5080(250)G1Z0190221 (01)04573596200520(11)211122(21)W5081(250)G1Z0190021 (01)04573596200520(11)211122(21)W5082(250)G1Z0190121 (01)04573596200520(11)211227(21)W5083(250)G1Z0190321 (01)04573596200520(11)211228(21)W5084(250)G1Z0210821 (01)04573596200520(11)220209(21)W5085(250)G1Z0210921 (01)04573596200520(11)220215(21)W5086(250)G1Z0211021 Serial Numbers: G560045319 G560048119 G560071519 G560075519 G1Z0040620 G1Z0063520 G1Z0244920 G1Z0048121 G1Z0083221 G1Z0094621 G1Z0094521 G1Z0115321 G1Z0123621 G1Z0190221 G1Z0190021 G1Z0190121 G1Z0190321 G1Z0210821 G1Z0210921 G1Z0211021 |
Match all identifying details in the current notice. A brand name alone is not enough.
Distribution
US Nationwide Distribution
States below are derived from the distribution text, including nationwide wording. They are not inferred from the firm's address.
- Alaska
- Alabama
- Arkansas
- Arizona
- California
- Colorado
- Connecticut
- Delaware
- Florida
- Georgia
- Hawaii
- Iowa
- Idaho
- Illinois
- Indiana
- Kansas
- Kentucky
- Louisiana
- Massachusetts
- Maryland
- Maine
- Michigan
- Minnesota
- Missouri
- Mississippi
- Montana
- North Carolina
- North Dakota
- Nebraska
- New Hampshire
- New Jersey
- New Mexico
- Nevada
- New York
- Ohio
- Oklahoma
- Oregon
- Pennsylvania
- Rhode Island
- South Carolina
- South Dakota
- Tennessee
- Texas
- Utah
- Virginia
- Vermont
- Washington
- Wisconsin
- West Virginia
- Wyoming
Dates in the source
- Report date
- Sep 21, 2022
- Recall initiation date
- Jul 12, 2022
- Center classification date
- Sep 15, 2022
FDA company pages use the listing date; enforcement records use initiation dates; CPSC uses recall date; NHTSA uses report-received date. These dates are not interchangeable.