- Product
- INTUITIVE Da Vinci Xi 8mm SureForm 30 Curved-Tip Stapler Da Vinci Xi|X REF 488530 INTUITIVE Da Vinci 8mm SureForm 30 Reload 30 mm Gray 4-Row 2.0 mm Xi|X REF 48230M INTUITIVE Da Vinci 8mm SureForm 30 Reload 30 mm White 4-Row 2.5 mm Xi|X REF 48230W INTUITIVE Da Vinci 8mm SureForm 30 Reload 30 mm Blue 4-Row 3.5 mm Xi|X REF 48230B
- Reason
- Potential staple deployment failure and device fragment generation
- Classification
- Class II
- Recalling firm
- Intuitive Surgical, Inc.
- Quantity
- 160 boxes of 488530-10 = 960 individual instruments 602 reload boxes = 7224 individual reloads
- Agency-reported status
- Ongoing
- Source record identifier
- Z-0340-2023
What the recall classes mean. Classification is an agency assessment, not individual medical advice.
Lot and product identifiers
| Label field | Details supplied by the agency |
|---|---|
| Lot, code or applicability | Model Name / Model Number / UDI-DI Code: Da Vinci Xi 8mm SureForm 30 instruments 488530-10 10886874121723 Da Vinci Xi 8mm SureForm 30 Grey Reload 48230M-02 10886874121938 Da Vinci Xi 8mm SureForm 30 White Reload 48230W-02 10886874121921 Da Vinci Xi 8mm SureForm 30 Blue Reload 48230B-02 10886874121914 All Serial Numbers |
Match all identifying details in the current notice. A brand name alone is not enough.
Distribution
U.S.: Arizona, California, Colorado, Florida, Illinois, Indiana, Louisiana, Maryland, Massachusetts, Michigan, Minnesota, Nevada, New York, North Carolina, Ohio, Oklahoma, Pennsylvania, South Carolina, Tennessee, Texas, Utah, Virginia, Washington, and Wisconsin. O.U.S.: None
States below are derived from the distribution text, including nationwide wording. They are not inferred from the firm's address.
Dates in the source
- Report date
- Dec 7, 2022
- Recall initiation date
- Oct 7, 2022
- Center classification date
- Nov 30, 2022
FDA company pages use the listing date; enforcement records use initiation dates; CPSC uses recall date; NHTSA uses report-received date. These dates are not interchangeable.