Free-Standing Professional Gas Ranges Recalled Due to Risk of Burn Hazard; Manufactured by Fisher & Paykel — CPSC recall 26419

Published notice; closure not supplied

The CPSC record supplies a notice and remedy, not a current closure determination.

Source date Apr 16, 2026. Retrieved Oct 1, 2026. Last updated Oct 1, 2026.

Archive changed Oct 1, 2026. USDA FSIS records are unavailable; check FSIS directly. Source coverage and dates.

What the record says

Product
This recall involves Fisher & Paykel 30, 36 and 48-inch stainless steel, free-standing or self-contained gas ranges (RGV3 models). The gas ranges come in natural gas or liquified petroleum gas. The recalled models have a serial number starting with EEV, ERV, EAV, EYV, EUV, ELV or RFV. The model and serial numbers are printed on the rating plate located on either the back of the product or behind the front kick strip. The recalled gas ranges include: Recalled Model Number Serial Number Date Code UPC Code RGV3-305-N EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843828494 RGV3-305-L EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843828500 RGV3-366-N EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843820023 RGV3-366-L EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843820030 RGV3-304-N EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843820047 RGV3-304-L EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843820054 RGV3-486GD-N EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843823833 RGV3-486GD-L EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843823840 RGV3-488N EEVxxxxxx to RFVxxxxxx May 25 to Jan 26 822843829736 RGV3-488L EEVxxxxxx to EKVxxxxxx May 25 to Oct 25 822843829743 RGV3-485GD-N EEVxxxxxx to EAVxxxxxx May 25 to Aug 25 822843829750 RGV3-485GD-L EEVxxxxxx to ELVxxxxxx May 25 to Dec 25 822843829767
Reason
The ovens in the ranges can experience a delayed ignition, causing gas to accumulate and the oven door to open from combustion, posing a burn hazard to users.
Classification
Not supplied
Recalling firm
Fisher & Paykel Appliances (Thailand) Co., Ltd, of Thailand
Quantity
About 433 (In addition, about 70 were sold in Canada)
Agency-reported status
Published recall notice
Source record identifier
26419

Open the official record

Lot and product identifiers

Label fieldDetails supplied by the agency
Lot, code or applicability822843828494; 822843828500; 822843820030; 822843820047; 822843820054; 822843823833; 822843823840; 822843829736; 822843829743; 822843829750; 822843829767; 191127003606; 191127003613; 191127003804

Match all identifying details in the current notice. A brand name alone is not enough.

Distribution

Not supplied

No US distribution state could be established from this record. Check the official notice.

Dates in the source

Last publish date
Apr 17, 2026

FDA company pages use the listing date; enforcement records use initiation dates; CPSC uses recall date; NHTSA uses report-received date. These dates are not interchangeable.