title: "PTW-FREIBURG Recalls: Agency-Reported Status and History (Oct 1, 2026) | Is It on Recall"
description: "Search PTW-FREIBURG recall records, lots, firms and dates. Reported status can be incomplete; use the linked agency notice for current instructions."
url: https://isitonrecall.com/brand/ptw-freiburg/
updated: 2026-10-01
site: "Is It on Recall"
language: en
---

[Home](https://isitonrecall.com/) / Brand archive

# PTW-FREIBURG recall records

**3** reported ongoing

3 records in this archive. Latest source date Aug 4, 2026.

FDA enforcement status can lag behind the recall lifecycle. An empty search or a reported termination is not a personal product-safety determination.

Archive changed Oct 1, 2026. USDA FSIS records are unavailable; [check FSIS directly](https://www.fsis.usda.gov/recalls). [Source coverage and dates](https://isitonrecall.com/sources/).

## Records and reported status

Aug 4, 2026 FDA device enforcement

### [Brand Name: VERIQA; Product Name: RT MonteCarlo 3D v3; Model/Catalog Number: S070031.520; Software Version: 3.1.18;](https://isitonrecall.com/recall/fda-device-z-3174-2026-brand-name-veriqa-product-name-rt-montecarlo-3d-v3-model-catalog-number-s070031-520-software-version/)

When a bolus is included in a treatment plan and sent for secondary dose calculation, the software accounts for it but does not display this clearly, which may lead users to incorrectly omit the bolus during treatment and deliver the prescribed dose to the ...

Class II Reported ongoing

Distribution: Worldwide - US Nationwide distribution in the states of GA, NY and the countries of Austria, Belgium, Switzerland, Czechia, Germany, Spain, France, Netherlands, Norway, Poland, ...

[Official source for Brand Name: VERIQA; Product Name: RT MonteCarlo 3D v3; Model/Catalog Number: S070031.520; Softwar...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-3174-2026%22)

Feb 8, 2024 FDA device enforcement

### [Software VERIQA (S070031), version 2.0 and 2.1- Software package for display, evaluation and digital processing of medical image data sets and treatment plans in radiation oncol...](https://isitonrecall.com/recall/fda-device-z-1181-2024-software-veriqa-s070031-version-2-0-and-2-1-software-package-for-display-evaluation-and-digital-proc/)

Software: If the user excludes voxels from the Gamma calculation that are below a dose threshold (Suppress gamma calculation), the Gamma Passing Rate (GPR) calculated for individual ROIs is not correct. The GPR calculated by VERIQA overestimates the correct...

Class II Reported ongoing

Distribution: GA

[Official source for Software VERIQA (S070031), version 2.0 and 2.1- Software package for display, evaluation and digi...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-1181-2024%22)

Jun 7, 2023 FDA device enforcement

### [BeamAdjust software Version 2.3.3 Ref: S080032 The following devices are affected when a relative calibration is performed using ArrayCal (module from BeamAdjust S080032, UDI-DI...](https://isitonrecall.com/recall/fda-device-z-2577-2023-beamadjust-software-version-2-3-3-ref-s080032-the-following-devices-are-affected-when-a-relative-cal/)

Generated calibration file will not be correct in case of a relative calibration of an OCTAVIUS Detector 1000 or OCTAVIUS Detector 1600, if a Tiff file or a DICOM data set is used as reference matrix. Therefore, the measurement result will be incorrect by u...

Class II Reported ongoing

Distribution: US Nationwide distribution.

[Official source for BeamAdjust software Version 2.3.3 Ref: S080032 The following devices are affected when a relative...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2577-2023%22)

## Reasons in these listed records

- When a bolus is included in a treatment plan and sent for secondary dose calculation, the software accounts for it but does not display this clearly, which may lead users to incorrectly omit the bolus during treatment and deliver the prescribed dose to the wrong tissue depth.
- Software: If the user excludes voxels from the Gamma calculation that are below a dose threshold (Suppress gamma calculation), the Gamma Passing Rate (GPR) calculated for individual ROIs is not correct. The GPR calculated by VERIQA overestimates the correct GPR. The evaluation...
- Generated calibration file will not be correct in case of a relative calibration of an OCTAVIUS Detector 1000 or OCTAVIUS Detector 1600, if a Tiff file or a DICOM data set is used as reference matrix. Therefore, the measurement result will be incorrect by using such a calibrat...

These examples come from this result page and are not a ranking of every recall reason.

## Checking PTW-FREIBURG

### Is there a recall on ptw-freiburg right now?

This archive contains 3 records, including 3 with agency-reported ongoing status. The status field can be incomplete or stale. Open the current official notice and match your exact product.

### How do I check my package or product?

Compare the product, firm and lot, date, model or serial identifiers with the notice. [Use the label-check guide](https://isitonrecall.com/guides/read-lot-codes/) if you need help locating an identifier.

### Does a matching name mean every item is included?

A name is a search match. The agency notice sets the affected products and identifiers. Do not assume that every item with the same name or brand belongs to the recall.

### What if the search finds no matching record?

This search has source and keyword limits. Missing records or a missing lot code do not establish that a product is unaffected. [Check source coverage](https://isitonrecall.com/sources/) and the agency's current notices.

### Where can I find older records?

Use [monthly archives](https://isitonrecall.com/archives/) or the local search. The initial import covers records dated from October 2021 where available; each source's actual first and latest dates appear on the coverage page.

## Keep checking

[Search PTW-FREIBURG](https://isitonrecall.com/check/?q=PTW-FREIBURG) [Browse related products](https://isitonrecall.com/products/) [Review source dates](https://isitonrecall.com/sources/)