**7** reported ongoing

7 records in this archive. Latest source date Jul 10, 2025.

FDA enforcement status can lag behind the recall lifecycle. An empty search or a reported termination is not a personal product-safety determination.

Archive changed Oct 1, 2026. USDA FSIS records are unavailable; [check FSIS directly](https://www.fsis.usda.gov/recalls). [Source coverage and dates](https://isitonrecall.com/sources/).

## Records and reported status

Jul 10, 2025 FDA device enforcement

### [Micro Joystick R-net. Electrical wheelchair component.](https://isitonrecall.com/recall/fda-device-z-2454-2025-micro-joystick-r-net-electrical-wheelchair-component/)

Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Class I Reported ongoing

Distribution: US Nationwide distribution in the state of TX.

[Official source for Micro Joystick R-net. Electrical wheelchair component.](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2454-2025%22)

Jul 10, 2025 FDA device enforcement

### [Multi Joystick R-net. Electrical wheelchair component.](https://isitonrecall.com/recall/fda-device-z-2455-2025-multi-joystick-r-net-electrical-wheelchair-component/)

Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Class I Reported ongoing

Distribution: US Nationwide distribution in the state of TX.

[Official source for Multi Joystick R-net. Electrical wheelchair component.](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2455-2025%22)

Jul 10, 2025 FDA device enforcement

### [IDM-MICRO-R. Electrical wheelchair component.](https://isitonrecall.com/recall/fda-device-z-2456-2025-idm-micro-r-electrical-wheelchair-component/)

Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Class I Reported ongoing

Distribution: US Nationwide distribution in the state of TX.

[Official source for IDM-MICRO-R. Electrical wheelchair component.](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2456-2025%22)

Jul 10, 2025 FDA device enforcement

### [IDM-MULTI-R. Electrical wheelchair component.](https://isitonrecall.com/recall/fda-device-z-2457-2025-idm-multi-r-electrical-wheelchair-component/)

Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Class I Reported ongoing

Distribution: US Nationwide distribution in the state of TX.

[Official source for IDM-MULTI-R. Electrical wheelchair component.](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2457-2025%22)

Jul 10, 2025 FDA device enforcement

### [All-round Joystick R-net Light. Electrical wheelchair component.](https://isitonrecall.com/recall/fda-device-z-2458-2025-all-round-joystick-r-net-light-electrical-wheelchair-component/)

Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Class I Reported ongoing

Distribution: US Nationwide distribution in the state of TX.

[Official source for All-round Joystick R-net Light. Electrical wheelchair component.](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2458-2025%22)

Jul 10, 2025 FDA device enforcement

### [IDM-ARLITE-R. Electrical wheelchair component.](https://isitonrecall.com/recall/fda-device-z-2459-2025-idm-arlite-r-electrical-wheelchair-component/)

Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

Class I Reported ongoing

Distribution: US Nationwide distribution in the state of TX.

[Official source for IDM-ARLITE-R. Electrical wheelchair component.](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2459-2025%22)

Nov 28, 2023 FDA device enforcement

### [Scoot Control R-net, Product Number P015-61. The Scoot Control is intended to support a wheelchair attendant in controlling or maneuvering a power chair](https://isitonrecall.com/recall/fda-device-z-0713-2024-scoot-control-r-net-product-number-p015-61-the-scoot-control-is-intended-to-support-a-wheelchair-att/)

In rare cases, the lever of the throttle can get temporarily stuck during the movement and does not come back to its neutral point by itself. If this happens during usage, an unwanted movement of the chair could be the result. An unwanted movement could res...

Class II Reported ongoing

Distribution: US States: TN, TX.

[Official source for Scoot Control R-net, Product Number P015-61. The Scoot Control is intended to support a wheelchai...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-0713-2024%22)

## Reasons in these listed records

- Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.
- In rare cases, the lever of the throttle can get temporarily stuck during the movement and does not come back to its neutral point by itself. If this happens during usage, an unwanted movement of the chair could be the result. An unwanted movement could result in damage to the...

These examples come from this result page and are not a ranking of every recall reason.

## Checking mo-Vis BVBA

### Is there a recall on mo-vis bvba right now?

This archive contains 7 records, including 7 with agency-reported ongoing status. The status field can be incomplete or stale. Open the current official notice and match your exact product.

### How do I check my package or product?

Compare the product, firm and lot, date, model or serial identifiers with the notice. [Use the label-check guide](https://isitonrecall.com/guides/read-lot-codes/) if you need help locating an identifier.

### Does a matching name mean every item is included?

A name is a search match. The agency notice sets the affected products and identifiers. Do not assume that every item with the same name or brand belongs to the recall.

### What if the search finds no matching record?

This search has source and keyword limits. Missing records or a missing lot code do not establish that a product is unaffected. [Check source coverage](https://isitonrecall.com/sources/) and the agency's current notices.

### Where can I find older records?

Use [monthly archives](https://isitonrecall.com/archives/) or the local search. The initial import covers records dated from October 2021 where available; each source's actual first and latest dates appear on the coverage page.

## Keep checking

[Search mo-Vis BVBA](https://isitonrecall.com/check/?q=mo-Vis%20BVBA) [Browse related products](https://isitonrecall.com/products/) [Review source dates](https://isitonrecall.com/sources/)