# Globus Medical, Inc. recall records

**6** reported ongoing

6 records in this archive. Latest source date Apr 3, 2025.

FDA enforcement status can lag behind the recall lifecycle. An empty search or a reported termination is not a personal product-safety determination.

Archive changed Oct 1, 2026. USDA FSIS records are unavailable; [check FSIS directly](https://www.fsis.usda.gov/recalls). [Source coverage and dates](https://isitonrecall.com/sources/).

## Records and reported status

Apr 3, 2025 FDA device enforcement

### [MAGEC 2 Rod, 5.0mm 90mm Standard; Version/Model: MC2-5090S;](https://isitonrecall.com/recall/fda-device-z-1657-2025-magec-2-rod-5-0mm-90mm-standard-version-model-mc2-5090s/)

Devices for the affected lot were not assembled according to product specifications. The distraction rod outer diameter was assembled with a 5.5mm rod versus the required 5.0mm.

Class II Reported ongoing

Distribution: US Nationwide distribution in the state of AR.

[Official source for MAGEC 2 Rod, 5.0mm 90mm Standard; Version/Model: MC2-5090S;](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-1657-2025%22)

Dec 15, 2023 FDA device enforcement

### [ExcelsiusGPS Cannula A, 9mm x 250mm, Cannula used with ball tip probes, Model No. 6143.2844](https://isitonrecall.com/recall/fda-device-z-1007-2024-excelsiusgps-cannula-a-9mm-x-250mm-cannula-used-with-ball-tip-probes-model-no-6143-2844/)

Devices may not be rendered sterile due to an internal gap that may be present on some devices causing increased difficulty cleaning prior to steam sterilization. There is an increased risk for infection, inflammation, local toxicity, systemic toxicity, sen...

Class II Reported ongoing

Distribution: Worldwide - US Nationwide and the countries of Australia, Austria, Belgium, Czech Republic, Germany, India, Indonesia, Ireland, Italy, Japan, Malaysia, Netherlands, Poland, Saud...

[Official source for ExcelsiusGPS Cannula A, 9mm x 250mm, Cannula used with ball tip probes, Model No. 6143.2844](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-1007-2024%22)

Dec 11, 2023 FDA device enforcement

### [Globus Medical Cranial Drill with Stop, 2.40mm - Instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref : 6143.1834S](https://isitonrecall.com/recall/fda-device-z-0995-2024-globus-medical-cranial-drill-with-stop-2-40mm-instruments-for-access-preparation-and-placement-of-cr/)

Sterile-packed Cranial Drills may not be sterile due to a breach in the packaging and/or may have discoloration near the drill tip.

Class II Reported ongoing

Distribution: Worldwide - US Nationwide and the countries of Czech Republic, Poland.

[Official source for Globus Medical Cranial Drill with Stop, 2.40mm - Instruments for access, preparation, and placeme...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-0995-2024%22)

Dec 11, 2023 FDA device enforcement

### [Globus Medical Cranial Drill with Stop, 3.20mm - instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref: 6143.1842S](https://isitonrecall.com/recall/fda-device-z-0996-2024-globus-medical-cranial-drill-with-stop-3-20mm-instruments-for-access-preparation-and-placement-of-cr/)

Sterile-packed Cranial Drills may not be sterile due to a breach in the packaging and/or may have discoloration near the drill tip.

Class II Reported ongoing

Distribution: Worldwide - US Nationwide and the countries of Czech Republic, Poland.

[Official source for Globus Medical Cranial Drill with Stop, 3.20mm - instruments for access, preparation, and placeme...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-0996-2024%22)

Dec 11, 2023 FDA device enforcement

### [Globus Medical Cranial Drill, 6.00mm - instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref: 6143.1870S](https://isitonrecall.com/recall/fda-device-z-0997-2024-globus-medical-cranial-drill-6-00mm-instruments-for-access-preparation-and-placement-of-cranial-devi/)

Sterile-packed Cranial Drills may not be sterile due to a breach in the packaging and/or may have discoloration near the drill tip.

Class II Reported ongoing

Distribution: Worldwide - US Nationwide and the countries of Czech Republic, Poland.

[Official source for Globus Medical Cranial Drill, 6.00mm - instruments for access, preparation, and placement of cran...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-0997-2024%22)

Dec 7, 2023 FDA device enforcement

### [ExcelsiusGPS Flat Panel Fluoroscopy Fixture Kit, Part number 6203.2100](https://isitonrecall.com/recall/fda-device-z-0642-2024-excelsiusgps-flat-panel-fluoroscopy-fixture-kit-part-number-6203-2100/)

A calibration error associated with the Flat Panel Fluoroscopy Fixture when used with ExcelsiusGPS for fluoroscopy workflow may lead to inaccurate navigation, which may result in device misplacement.

Class I Reported ongoing

Distribution: Domestic distribution to the following states: CA, CO, MT, SC, WA. International distribution to Germany and UK.

[Official source for ExcelsiusGPS Flat Panel Fluoroscopy Fixture Kit, Part number 6203.2100](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-0642-2024%22)

## Reasons in these listed records

- Devices for the affected lot were not assembled according to product specifications. The distraction rod outer diameter was assembled with a 5.5mm rod versus the required 5.0mm.
- Devices may not be rendered sterile due to an internal gap that may be present on some devices causing increased difficulty cleaning prior to steam sterilization. There is an increased risk for infection, inflammation, local toxicity, systemic toxicity, sensitivity, and cross-...
- Sterile-packed Cranial Drills may not be sterile due to a breach in the packaging and/or may have discoloration near the drill tip.
- A calibration error associated with the Flat Panel Fluoroscopy Fixture when used with ExcelsiusGPS for fluoroscopy workflow may lead to inaccurate navigation, which may result in device misplacement.

These examples come from this result page and are not a ranking of every recall reason.

## Checking Globus Medical, Inc.

### Is there a recall on globus medical, inc. right now?

This archive contains 6 records, including 6 with agency-reported ongoing status. The status field can be incomplete or stale. Open the current official notice and match your exact product.

### How do I check my package or product?

Compare the product, firm and lot, date, model or serial identifiers with the notice. [Use the label-check guide](https://isitonrecall.com/guides/read-lot-codes/) if you need help locating an identifier.

### Does a matching name mean every item is included?

A name is a search match. The agency notice sets the affected products and identifiers. Do not assume that every item with the same name or brand belongs to the recall.

### What if the search finds no matching record?

This search has source and keyword limits. Missing records or a missing lot code do not establish that a product is unaffected. [Check source coverage](https://isitonrecall.com/sources/) and the agency's current notices.

### Where can I find older records?

Use [monthly archives](https://isitonrecall.com/archives/) or the local search. The initial import covers records dated from October 2021 where available; each source's actual first and latest dates appear on the coverage page.

## Keep checking

[Search Globus Medical, Inc.](https://isitonrecall.com/check/?q=Globus%20Medical%2C%20Inc.) [Browse related products](https://isitonrecall.com/products/) [Review source dates](https://isitonrecall.com/sources/)