# Accuray Incorporated recall records

**2** reported ongoing

4 records in this archive. Latest source date Jun 16, 2026.

FDA enforcement status can lag behind the recall lifecycle. An empty search or a reported termination is not a personal product-safety determination.

Archive changed Oct 1, 2026. USDA FSIS records are unavailable; [check FSIS directly](https://www.fsis.usda.gov/recalls). [Source coverage and dates](https://isitonrecall.com/sources/).

## Records and reported status

Jun 16, 2026 FDA device enforcement

### [Cyberknife Treatment Deliver System equipped with the Xchange Robotic Collimator Changer; Linear Accelerator](https://isitonrecall.com/recall/fda-device-z-2640-2026-cyberknife-treatment-deliver-system-equipped-with-the-xchange-robotic-collimator-changer-linear-acce/)

In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collimator may release ...

Class II Reported ongoing

Distribution: Worldwide distribution - US Nationwide and the countries of China, Colombia, Czech Republic, France, Hong Kong, Japan, Korea, Republic of, Latvia, Mexico, Myanmar, Saudi Arabia,...

[Official source for Cyberknife Treatment Deliver System equipped with the Xchange Robotic Collimator Changer; Linear ...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2640-2026%22)

Jun 16, 2026 FDA device enforcement

### [Cyberknife Treatment Deliver System equipped with the Xchange Robotic Collimator Changer; Linear Accelerator](https://isitonrecall.com/recall/fda-device-z-2644-2026-cyberknife-treatment-deliver-system-equipped-with-the-xchange-robotic-collimator-changer-linear-acce/)

In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collimator may release ...

Class II Reported ongoing

Distribution: Worldwide - US Nationwide and and the countries of Australia, Austria, Belgium, Brazil, Canada, Chile, China, Colombia, Czech Republic, Egypt, France, Germany, Greece, Hong Kong...

[Official source for Cyberknife Treatment Deliver System equipped with the Xchange Robotic Collimator Changer; Linear ...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2644-2026%22)

Dec 23, 2024 FDA device enforcement

### [CyberKnife Treatment Delivery System, REF 0660000 The CyberKnife System may be labeled as CyberKnife M6TM or VSI TM Robotic Surgery System. The CyberKnife Treatment Delivery Sys...](https://isitonrecall.com/recall/fda-device-z-1023-2025-cyberknife-treatment-delivery-system-ref-0660000-the-cyberknife-system-may-be-labeled-as-cyberknife/)

Snap rings may become partially or completed detached from the shafts within the internal mechanism. Uncontrolled rotation may occur on the left and right roll axes when the rings are removed or damaged.

Class II Reported completed

Distribution: Worldwide - US Nationwide distribution.

[Official source for CyberKnife Treatment Delivery System, REF 0660000 The CyberKnife System may be labeled as CyberKn...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-1023-2025%22)

Aug 3, 2023 FDA device enforcement

### [Upper roller bracket (part number 1088370) for the Gen2 gantry enclosure for the Radixact Treatment Delivery System.](https://isitonrecall.com/recall/fda-device-z-2489-2023-upper-roller-bracket-part-number-1088370-for-the-gen2-gantry-enclosure-for-the-radixact-treatment-de/)

It is possible the upper roller bracket in the Radixact System gantry enclosure may not provide enough clearance for service personnel to use a jib crane for moving components while servicing the system, resulting in possible injury to the service personnel.

Class II Reported completed

Distribution: Worldwide - US Nationwide distribution in the states of CA, GA, IL, LA, NJ, OR, PA, SC, SD, TX, and WA. There was government distribution and no military distribution. The count...

[Official source for Upper roller bracket (part number 1088370) for the Gen2 gantry enclosure for the Radixact Treatme...](https://api.fda.gov/device/enforcement.json?search=recall_number%3A%22Z-2489-2023%22)

## Reasons in these listed records

- In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collimator may release and fall from the ho...
- Snap rings may become partially or completed detached from the shafts within the internal mechanism. Uncontrolled rotation may occur on the left and right roll axes when the rings are removed or damaged.
- It is possible the upper roller bracket in the Radixact System gantry enclosure may not provide enough clearance for service personnel to use a jib crane for moving components while servicing the system, resulting in possible injury to the service personnel.

These examples come from this result page and are not a ranking of every recall reason.

## Checking Accuray Incorporated

### Is there a recall on accuray incorporated right now?

This archive contains 4 records, including 2 with agency-reported ongoing status. The status field can be incomplete or stale. Open the current official notice and match your exact product.

### How do I check my package or product?

Compare the product, firm and lot, date, model or serial identifiers with the notice. [Use the label-check guide](https://isitonrecall.com/guides/read-lot-codes/) if you need help locating an identifier.

### Does a matching name mean every item is included?

A name is a search match. The agency notice sets the affected products and identifiers. Do not assume that every item with the same name or brand belongs to the recall.

### What if the search finds no matching record?

This search has source and keyword limits. Missing records or a missing lot code do not establish that a product is unaffected. [Check source coverage](https://isitonrecall.com/sources/) and the agency's current notices.

### Where can I find older records?

Use [monthly archives](https://isitonrecall.com/archives/) or the local search. The initial import covers records dated from October 2021 where available; each source's actual first and latest dates appear on the coverage page.

## Keep checking

[Search Accuray Incorporated](https://isitonrecall.com/check/?q=Accuray%20Incorporated) [Browse related products](https://isitonrecall.com/products/) [Review source dates](https://isitonrecall.com/sources/)